Injection molding machine strong magnetic mold thimble reset protection switch controller is a device used for injection molding machine thimble reset protection, with strong magnetic reset function and strong durability. The controller is fixed to the mold by strong magnetic adsorption, and when the thimble is used up, it can be automatically reset with a simple push, which is easy to operate and efficient
How it works
The working principle of the protection switch controller of the high magnetic mold thimble reset is based on the high magnetic reset function. When the thimble is used up, the switch will be automatically reset with a gentle push, without complicated operation, greatly improving work efficiency and convenience.
Application scenarios
The controller is widely used in thimble reset protection of various injection molding machines. Whether in industrial production or in daily use, it can provide stable and reliable protection function to ensure the accurate reset of the thimble and avoid mold damage or production accidents caused by the failure of the thimble to reset.
一、The function of the injection mold thimble protection switch
Injection mold thimble protection switch is one of the injection molding machine mold protection safety equipment, mainly used to protect the mold thimble. When the thimble of the mold is abnormal, the switch can detect it in time, so that the injection molding machine can stop immediately, and avoid the damage of the mold or the injection molding machine caused by the thimble fault.
二、Wiring method for thimble protection switch of injection mold
1. Disconnect the power supply before wiring, and check whether the wiring cable is intact.
2. Connect the COM and NO pins of the switch to the corresponding lines of the control circuit of the injection molding machine respectively.
3. If the switch is also equipped with NC pin, you can pay attention to it when wiring. If an NC pin is required, connect the NC pin to another signal wire in the control circuit of the injection molding machine.
Notes:
1. In order to ensure normal operation, please choose a reliable thimble protection switch of injection molding tool, and make correct wiring according to the product manual.
2. Before the operation of the injection molding machine, the thimble protection switch and wiring must be checked to ensure that it is correct before it can be put into production.
3. In the process of use, if the switch is found to be faulty or abnormal, please replace it in time or seek professional maintenance help.
三、Three, injection mold thimble protection switch maintenance suggestions
1. Overhaul and clean the switch regularly to maintain a dry and clean environment.
2. Avoid machine vibration or impact, avoid strong electromagnetic interference, avoid sun and humidity.
3. Prevent the special odor caused by the oxidation of lubricating oil in the injection mold or the surface of the mold from affecting the switch